首頁>產(chǎn)品中心>日本光明北川式氣體檢測(cè)管>氣體快速檢測(cè)管>156S氟化氫HF氣體檢測(cè)管156S HYDROGEN FLUORIDE 0.17-30ppm

氟化氫HF氣體檢測(cè)管156S HYDROGEN FLUORIDE 0.17-30ppm

簡要描述:

氟化氫HF氣體檢測(cè)管156S HYDROGEN FLUORIDE 0.17-30ppm,是一種*的腐蝕劑,有劇毒。它是無色的氣體,但是在空氣中,只要超過3ppm就會(huì)產(chǎn)生刺激的味道。八小時(shí)日時(shí)量平均容許濃度(TLV):3ppm,短時(shí)間時(shí)量平均容許濃度(S):6ppm,呼吸防護(hù):30ppm以下:含防HF 濾罐的動(dòng)力型空氣凈化式或全面型化學(xué)濾罐式呼吸防護(hù)具、含防HF 濾罐的防毒面罩、全面型自攜式或供氣式呼吸防護(hù)具

更新時(shí)間:2025-01-08

發(fā)郵件給我們:554328895@qq.com

分享到: 1
在線留言
氟化氫HF氣體檢測(cè)管156S HYDROGEN FLUORIDE 0.17-30ppm

氟化氫HF氣體檢測(cè)管156S HYDROGEN FLUORIDE 0.17-30ppm

Tube 56S

1. PERFORMANCE
1) Measuring range :0.5-30 ppm 0.25-15 ppm
Number of pump strokes 3(300ml) 6(600ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.2 ppm(300ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 3 pump strokes
8) Colour change :Greenish yellow→Pink
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
PH indicator is discoloured by Hydrogen fluoride.
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
1
0.5
5
10
15
20
25
30
300ml
ppm

????
156S HYDROGEN FLUORIDE
Substance Interference Coexistence
Chlorine FIG.1 Similar stain is produced. Higher readings are given.
Hydrogen chloride FIG.2 〃〃
(NOTE)
1)This detector tube is affected by ambient temperature and humidity,therefore, it is necessary to compensate
the reading of gas detector tube with the following equation and correction coefficient table.
Actual concentration=Reading Value×Correction Coefficient
2)In case of 6 pump strokes, following formula is available for the actual concentration.
Actual concentration=1/2×Temp./R.H. corrected value
0
30
40
20
10
Chlorine〔ppm〕?
FIG.1 Influence of Chlorine
Hydrogen fluorine
indicating value 〔ppm〕
2 4 6 8 10 0
30
40
20
10
Hydrogen chloride〔ppm〕?
FIG.2 Influence of Hydrogen chloride
Hydrogen fluorine
indicating value 〔ppm〕
10 20 30
TEMP./R.H.CORRECTION COEFFICIENT TABLE
Relative Temperature
Humidity 0℃ 10℃ 20℃ 30℃ 40℃
(%) (32°F) (50°F) (68°F) (86°F) (104°F)
30 0.9 0.7 0.6 0.55 0.5
40 1.6 1.0 0.8 0.65 0.6
50 2.6 1.3 1.0 0.7 0.7
60 - 2.2 1.5 1.1 0.8
70 - - 2.7 1.6 0.9
80 - - - 2.9 1.1

| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |